One of the most common questions I receive from my customers is the following: Where will the air for burning the fireplace or the wood stove? Will it be from inside or outside the house, how will it be replenished, how much air it needs to work, open an intake port, build a conduit in case the fireplace does not touch an exterior wall?

FIREPLACES, WOODS AND EXTERIOR AIR FOR COMBUSTION
An attempt to answer the above questions is the following article. It comes from https://www.woodheat.org/the-outdoor-air-myth-exposed.html of Wood Heat Organization Inc. of a Canadian, non-profit, NGO that as a purpose of its operation, as stated on its home page, has spreading the know-how on the responsible use of wood as a domestic fuel.

“The Outdoor Air Myth Exposed
Outdoor combustion air was a good idea . . . until it was studied

Building codes in various jurisdictions in North America require that fireplaces, and in some cases wood stoves, be provided with a source of combustion air from outdoors. This mostly takes the form of :

  • with a duct attached running to the stove or fireplace. This possibility exist in few manufactors.
  • Μa four-inch diameter hole in an outside wall, connected either directly to the firebox or to a location where it can be heated by the fire before entering the room.
  • Sometimes the air is just dumped somewhere in the room.

There seem to be three theories behind this outdoor air supply, depending on who is doing the explaining:

  • The first is to replace the air sucked out of the house by the wood burner, based on the idea that houses are airtight and the wood burner will use up all the oxygen.
  • The second is to reduce the risk of smoking into the room, even when the room is depressurized by a big fan like a kitchen range exhaust.
  • The third is to save energy by using outdoor air rather than indoor air that has already been heated.

But it doesn’t matter which theory you pick; none of the three stands up to scientific scrutiny. It turns out that the most consistently reliable place from which to take combustion air is the room where the appliance is installed. Forget about outdoor air supplies as a way to make wood stoves and fireplaces work better or be more efficient. If your local building code forces you to install outdoor air, you will have no choice, but be aware that it will not reliably improve the performance of your wood burning appliance or result in higher efficiency of the system.

The outdoor combustion air myth got started almost fifty years ago when safety and construction standards were written for mobile homes. Because they were small and factory-built, it was believed that mobile homes were air tight. As a result, all wood, oil and gas furnaces, stoves and fireplaces had to get their air from outdoors. Because these air supplies were invariably routed straight down into the ventilated crawl space under the mobile home, they didn’t cause too many problems, so it was assumed that they actually worked.

In the 1980s, when large exhaust systems – like downdraft kitchen range exhausts – began to cause spillage from fireplaces and stoves in reasonably tight houses, a consensus quickly formed around the idea of bringing combustion air from outdoors, just as had been done in mobile homes for decades. Such certainty existed among housing technologists and regulatory authorities on the issue of outdoor combustion air that it was made mandatory in most building codes. Unfortunately, the decision to enforce mandatory outdoor air rules was made before research was done to investigate how they actually work.
The supposed benefits of outdoor air are not supported by research results. Laboratory and field reports have revealed that providing outdoor air is not a simple or effective cure for spillage, and that some designs could create a fire hazard.

Two forms of outdoor air supply have been used: passive make-up type air supplies and direct-to-combustion chamber air supplies.

Passive make-up air supplies

Εξωτερικός αέρας καύσης 1 Passive air inlets are nothing more than holes in the wall. Wind effects
Εξωτερικός αέρας καύσης 2
 may force air into the house or suck it out of the house, depending on the location of the hole relative to wind direction.A passive make-up type air supply is one that is not connected directly to the fireplace or stove combustion chamber. Since it is connected only to the house environment and not to the appliance, it flows air into a house only when the pressure inside is lower than the pressure outdoors, since air only flows to zones of lower pressure. Passive air supplies don’t make wood burners work better, they just make the house leakier.
Wind effects around the house also affect the direction and volume of flow through a passive inlet. If the weather hood of a passive inlet is on the windward side of a building, wind pressure is likely to force air into the building; if the weather hood is on the downwind side, the negative pressure zone created by the wind is likely to draw air out of the house, possibly depressurizing it.

Passive air inlets do not supply combustion air, but flow air only in response to pressure differences. Here, the flow direction depends on where in the house the passive hole is located. More importantly, it is misleading to think of the hole in the wall approach as supplying combustion air. In fact, passive air supplies provide air only in response to pressure differences. In cold weather, when temperature difference produces a pressure difference due to stack effect, if a passive make-up air supply is located below the neutral pressure plane of the house (and there is no wind effect and no exhaust systems are operating), air will flow into the house. If, on the other hand, the passive inlet is located above the house neutral pressure plane, air will flow out.
It is useful to keep in mind a key physical principle:
AIR FLOWS TO ZONES OF LOWER PRESSURE through any available opening.
The real problem with the passive make-up air strategy is that it does not reliably supply combustion air, nor does it reliably reduce combustion spillage. Under favorable conditions it may tip the balance of driving and adverse pressures in favor of successful venting. This is why some wood heating specialists have reported performance improvements after the installation of a passive supply. However, it is also possible for a passive supply to cause spillage if air is drawn out of the house into a low-pressure zone caused by wind effects. A remedial strategy that only works sometimes, and that may make the problem worse, is not a good strategy. A passive make-up air supply is really nothing more than another uncontrolled leak in the house envelope. A leaky house envelope is no guarantee of successful venting.

Direct-to-combustion chamber outdoor air supplies

1. Outdoor air supplies Εξωτερικός αέρας 3connected directly to the stove or fireplace combustion chamber may seem like a good idea and it was once believed that a direct supply would isolate the combustion appliance from room pressure variations.However, two key findings from the research into outdoor air supplies serve as cautions against the widespread use of direct combustion air supplies. ( or wood stove )
Smoke leakage can occur, even when the appliance has tightly sealed doors. If an exhaust fan like a kitchen range hood depressurizes the room to a level greater than the draft produced in the chimney, combustion gases will leak from any available opening, such as gaps in gaskets and the joints between factory-built chimney sections (illustration below). Because air flows to zones of lower pressure, a tightly sealed combustion/venting system will spill a smaller volume of smoke into the room than a leakier system, but it will still leak unless it is perfectly sealed. Perfect sealing is not a realistic goal because it would be difficult to achieve at the time of construction or installation and is unlikely to be permanent.
2. Direct air supplies can reverse flow direction if the weather hood is exposed to a negative pressure in excess of chimney draft (illustration below). Hot exhaust gas passing through a combustion air duct constitutes a potential fire hazard. The pressure effects of wind force around buildings can be far more powerful than the pressures produced by chimney draft. Chimney draft ranges from zero to about 50 Pa (0.2 in. water column) in normal residential installations, whereas high wind effects can produce pressures around houses up to 100 Pa. Evidence of wind-induced reversals in combustion air ducts is becoming more common now that so many systems have been installed. When servicing systems with direct outdoor combustion air ducts, look for soot or staining inside the duct. If there is any evidence of reversal, disconnect the duct and plug the hole in the house envelope.
It has been suggested that a direct combustion air supply to a woodburning appliance would eliminate its air consumption impact on other chimney vented combustion equipment in the building. However, when their doors are closed, wood heating appliances exhaust comparatively little air from the dwelling. Wood stoves with gasketed doors consume in the range of 10 – 25 cubic feet per minute of air, which is a tiny amount of air, much less than an oil furnace, for example. Since the air consumption of a wood stove is so low, the risk of reversal of a ducted combustion air supply outweighs any advantage gained by bringing air from outdoors.
An open fireplace, in contrast, can exhaust such a large volume of air that it could affect the operation of, for example, a conventional gas-fired furnace or water heater. But direct combustion air supplies cannot effectively be connected to a fireplace without doors because insufficient pressure difference is created to drive the flow. In other words, there is no simple way to provide the large volume of air used by a fireplace by supplying it from outdoors, except perhaps by opening a window.
There may be circumstances in which a direct outdoor air supply is considered necessary. If it is decided to supply combustion air directly to a firebox, it should be done with full awareness that spillage is still likely if the room becomes seriously depressurized and, for safety reasons, steps should be taken to control temperatures on combustibles adjacent to the air supply duct in case wind effects lead to a flow reversal.
Despite the fact that it is enshrined in some building codes and its adherents are often vocally forceful, there is no scientific evidence to suggest that outdoor air supplies, either direct to the combustion chamber or indirect supplies to the living space, are reliable and effective remedial measures for combustion spillage from the appliance for which the supply is intended.
A stove vented by natural draft needs a reliable and unrestricted supply of combustion air. Since passive outdoor air supplies in reasonable sizes are ineffective and since direct combustion air supplies are unreliable and potentially dangerous, other options must be considered. The most obvious alternative is to take combustion air from inside the building.
Ideally, a stove operating on natural draft takes its combustion air from a neutral pressure environment so that the air supply is steady and consistent. Perfection would be an air supply provided at neutral pressure and with no resistance to flow. Wood burners consume combustion air in response to the amount of chimney draft produced by the heat of their own flue gases. A stove or fireplace will be fussy to start and likely to spill when it tries to get its combustion air from a seriously depressurized building. The extent of building depressurization is deducted from potential chimney draft, like this:
theoretical draft – depressurization = net draft
Building depressurization competes directly with chimney draft. If the chimney wins the competition, the flow direction is up (successful venting); if the fan causing the depressurization wins, the flow is down (spillage or back drafting).
The advantage of taking combustion air directly from the room in which the stove or fireplace is installed is that the building envelope moderates the effect of wind on the air supply by damping out wind-induced pressure fluctuations. The pressure inside the house will still be affected by wind to some extent, but the flow resistance offered by the envelope tends to remove the peaks and valleys of high and low pressure caused by wind gusts.
It is sometimes assumed that taking air from outside through a duct saves energy because the stove doesn’t use up indoor air and cause outdoor air to be drawn in through leaks to replace it. But the assumed heating deficit is so small as to be insignificant. The average air consumption of a modern wood heater is in the range of 10 – 25 cfm, which is very small compared to the natural leakage rate of houses. Building scientists say that the air in a house must be exchanged at least every three hours, or one-third of an air change per hour, to control moisture from cooking and washing and to manage odors. One third of an air change in a 1500 square foot house is 4000 cubic feet, or 66 cfm. Note that this is the absolute minimum air change for healthy living and that most houses older than 20 years have natural leakage rates far higher than this in winter. So, the air consumption of a wood stove is a tiny part of a much larger exchange of air between the house and outdoors.
The main disadvantage of taking air from inside the house is that the pressure environment can be adversely affected by powered exhausts. However, depressurization caused by powered exhaust flows is predictable and manageable, unlike the more random and unpredictable effects of wind on outdoor air supplies. The worst-case indoor air pressure environment can be measured using the house pressure test procedure, and can be controlled either by limiting exhaust flows or by installing a powered make-up air system.
In general, therefore, wood stoves and fireplaces that are vented by natural chimney draft should draw the air for combustion from the room in which they are located. Where necessary the indoor air pressure should be controlled to minimize depressurization.
JG”

Εξωτερικός αέρας καύσης 4

We need to remind that a energy save fireplace or stove with a closed door it consumes 18 up to 45 m³ per hour. In contrast with an open fireplace if we connect the outside air directly to the chamber the created air flow is low due to the small difference in pressure . In other words there is no way to supply with air a traditional fireplace unless we open a window. The scientists that specialized in the hygiene of modern houses persist that is imperative a house o refresh it’s air every 3 hours. Essential for the correct managemant of odors and moisture from cooking.  For a town house of 150 m² coming into the house. Enough quantity to cove the needs of your energy save fireplace.

The major down side of feeding with air the energy save fireplace from inside the house is that the pressured environment can affect the kitchen venting. The manufactors of those systems suggest during their operation to open slighttly the window, to avoid the decompression of the house. This is something predictable and manageable incontrast to the random and unpredictable consequences of the wind that inverse the pressure balance in the house, when we supply the chamber with air from outside.

In conclusion the energy save appliances that burn wood should use the inside air for their operating. For our healthy living we check the air pressure and avoid the depressurization of our home. Do not forget, the secret for the proper function of the fireplace is the warm chimney.